Part Number Hot Search : 
ONTROL SF2037C BSS145 PPF430E N25F80 LTC34 D23C1 CLS62B
Product Description
Full Text Search
 

To Download 11121113 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  soldertacts shielded one-piece solder contacts applications one-piece controlled-sol- dering soldert acts contacts connectors are designed to ter minate coaxial cables, shielded wir es, and twisted pairs faster and more reli- ably than any other method. soldert acts contacts elimi - nate the variables associat - ed with har d-to-handle crimping. their one-step installation accelerates production while reducing handling and installed costs. controlled soldering soldertacts contacts pro- vide the optimum amount and type of solder and flux in pr efluxed solder pr eforms to control soldering and reduce operator sensitivity. the geometry of the coaxial cable is car ried thr ough the connector to eliminate separate pins, help r educe cross talk, and improve shielding effectiveness and signal transmission. soldertacts contacts pro- vide simultaneous electrical connection and strain relief. heat-shrinkable tubing insulations eliminate stress concentration on the wire within the contact. because the insulation is transpar ent and inspection windows are provided, terminations are fully inspectable. compatibility the design versatility of soldert acts contacts makes them exceptionally well suit- ed to military applications, along with commer cial aerospace, instrumentation and computers. soldert acts products are compatible with most standard connec- tor cavities. soldertacts contacts ar e inter mateable and intermountable with contacts qualified to the indicated specification. soldertacts shielded contacts can be terminated with standar d raychem heating tools. once termi- nated, they can be installed into connector cavities with standard insertion and extraction tools. they are replaceable without cutting and restripping or shorten- ing the cable. specifications/approvals series raychem d-602 d-6002 product facts n reliable one-piece solder contacts: through-connector shielding reduces cross- talk, and improves signal transmission n one-step installation n s older joints are strong and r eliable n terminations are fully inspectable n termination for coax cables, shielded wires, twisted pairs, triaxial cables, for a variety of commercial and military connectors shielded contacts 8-67 catalog 1654025 dimensions are in millimeters dimensions are shown for usa: 1-800-522-6752 south america: 55-11-3611-1514 revised 12-04 and inches unless otherwise reference purposes only. canada: 1-905-470-4425 japan: 81-44-900-5102 specified. v alues in brackets specifications subject mexico: 01-800-733-8926 singapore: 65-4866-151 www.tycoelectronics.com are u.s. equivalents. to change. c. america: 52-55-5-729-0425 uk: 44-1793-528171 8 e l e c t r i c a l i n t e r c o n n e c t p r o d u c t s a vailable in: americas n europe n asia pacific n
shielded contacts 8-68 catalog 1654025 dimensions are in millimeters dimensions are shown for usa: 1-800-522-6752 south america: 55-11-3611-1514 revised 12-04 and inches unless otherwise reference purposes only. canada: 1-905-470-4425 japan: 81-44-900-5102 specified. v alues in brackets specifications subject mexico: 01-800-733-8926 singapore: 65-4866-151 www.tycoelectronics.com are u.s. equivalents. to change. c. america: 52-55-5-729-0425 uk: 44-1793-528171 soldertacts shielded one-piece solder contacts (continued) c ontact c able diameter r aychem m ilitary wire s oldertacts size polarity cable type specification jod sod dod cod (awg) part no. mis-20067/5-001? 1.78?.70 1.65?.79 .76?.03 .23?51 24?2 d-602-16 12 s coaxial [.070?185] [ .065?1 10] [.030?080] [.009?020] mis-20067/6-001? 1 .78?.70 1.65?.79 .76?.03 .23?51 24?2 d -602-17 12 p coaxial [.070?185] [.065?110] [.030?080] [.009?020] 1.52?.30 1.68?.13 . 91?.75 .30?66 24?0 d-602-46 16 p coaxial [.060?130] [.066?089] [.036?069] [.012?026] 1.52?.30 1.68?.13 .91?.75 .30?66 26?2 d-602-47 16 s coaxial [.060?130] [.066?089] [.036?069] [.012?026] .76?.24 .28?79 24?0 d-602-56 16 p t winax [.030?049] [.011?031] .76?.24 .28?79 24?0 d-602-57 16 s twinax [.030?049] [.01 1?031] ?these soldertacts contacts are on qualified parts list for indicated specification. engineering convection standard (hot air) heating contact contact (termination at-1319 repair insertion removal part numbers instructions) adapter w and t ool tool d-602-46/47 es61137 at-1319-17 * ad-1525 ad-1526 d-602-56/57 es61138 (m81969/17-04) (m81969/19-08) d-602-16/17 es61161 *could be developed. note: aa-400 superheater compressed air heating tool shown on page 10-2 can be used for installation. another option is the steinel general purpose hot-air heating tool shown on page 10-13. soldertacts product construction, mil-c-26482 series soldertacts series: mil-c-26482 tooling selection guide jacket (jod) shield (sod) dielectric (dod) conductor (cod)
shielded contacts 8-69 catalog 1654025 dimensions are in millimeters dimensions are shown for usa: 1-800-522-6752 south america: 55-11-3611-1514 revised 12-04 and inches unless otherwise reference purposes only. canada: 1-905-470-4425 japan: 81-44-900-5102 specified. v alues in brackets specifications subject mexico: 01-800-733-8926 singapore: 65-4866-151 www.tycoelectronics.com are u.s. equivalents. to change. c. america: 52-55-5-729-0425 uk: 44-1793-528171 8 e l e c t r i c a l i n t e r c o n n e c t p r o d u c t s soldertacts shielded one-piece solder contacts (continued) c ontact cable diameter raychem m ilitar y wire soldertacts size polarity cable type specification jod sod dod cod (awg) part no. m is-20067/2-002 a 1.52?.35 1.68?.13 .91?.78 .23?89 2 6?2 d -602-44 16 p coaxial [ .060-.132] [.066-.084] [.036-.070] [.009-.035] m is-20067/1-001 a 1.52?.35 1.68?.13 .91?.78 .23?89 2 6?2 d-602-45 16 s coaxial [.060-.132] [.066-.084] [.036-.070] [.009-.035] m is-20067/4-001 a .76?.24 .28?79 2 4?0 d-602-54 16 p twisted pair [ .030-.049] [.011-.031] mis-20067/3-001 a .76?.24 .28?79 24?0 d -602-55 16 s twisted pair [ .030-.049] [.011-.031] m39029/79 b 1.52?.35 1.68?.13 .91?.68 .30?66 26?2 d-602-72 16 p coaxial [.060-.132] [.066-.084] [.036-.066] [.012-.026] m39029/80 b 1.52?.35 1.68?.13 .91?.68 .30?66 26?2 d-602-73 16 s coaxial [.060-.132] [.066-.084 ] [.036-.066] [.012-.026] m39029/40 b 1.52?.35 1.68?.13 .91?.68 .30?66 26?2 d-602-76 16 p coaxial [.060-.132] [.066-.084 ] [.036-.066] [.012-.026] m39029/41 b 1.52?.35 1.68?.13 .91?.68 .30?66 26?2 d-602-77 16 s coaxial [.060-.132] [.066-.084 ] [.036-.066] [.012-.026] .76?.24 .28?79 24?0 d-602-0126 16 p twisted pair c [.030-.049] [.011-.031] .76?.24 .28?79 24?0 d-602-0127 16 s twisted pair c [.030-.049] [.011-.031] 1.52?.35 1.68?.13 .91?.78 .23?46 28?2 d-602-0172 16 p coaxial [.060-.132] [.066-.084 ] [.036-.070] [.009-.018] mis-20067/2-001, 003 a 1.52?.35 1.68?.13 .91?.78 .23?46 28?2 d-602-0173 16 s coaxial [.060-.132] [.066-.084 ] [.036-.070] [.009-.018] mis-20067/8-001 a 1.40?.15 .64?.57 16?0 d-610-09 16 p power [.055-.124] [.025-.062] mis-20067/7-001 a 1.40?.15 .64?.57 16?0 d-610-10 16 s power [.055-.124] [.025-.062] a these soldertacts contacts are on the qualified parts list for indicated specification. b these soldertacts contacts are intermateable and intermountable with contacts qualified to the indicated specification; they replace crimp-style termination. c these soldertacts contacts are designed for twisted-pair cable per mil-std-1553b. s oldertacts product construction, mil-c-28748 series soldertacts series: mil-c-28748 series jacket (jod) shield (sod) dielectric (dod) conductor (cod)
shielded contacts 8-70 catalog 1654025 dimensions are in millimeters dimensions are shown for usa: 1-800-522-6752 south america: 55-11-3611-1514 revised 12-04 and inches unless otherwise reference purposes only. canada: 1-905-470-4425 japan: 81-44-900-5102 specified. v alues in brackets specifications subject mexico: 01-800-733-8926 singapore: 65-4866-151 www.tycoelectronics.com are u.s. equivalents. to change. c. america: 52-55-5-729-0425 uk: 44-1793-528171 soldertacts shielded one-piece solder contacts (continued) convection (hot air) heating s oldertacts part engineering standard at-1319 repair s eries no. (termination instructions) a dapter wand d -602-44/45 es61133 at-1319-14 ad-1480 d -602-0172/0173 es61240 d -602-54/55 es61132 d -602-0126/0127 es61199 7 48 d -610-09/10 es61187 at-1319-15 ad-1571 d -602-72/73 es61135 at-1319-18 ad-1486 d-602-76/77 es61164 at-1319-20 ad-1554 c ontact contact s oldertacts series insertion tool removal tool s pecial tools a d-1457a ad-1464 7 48 * a d-1447 ( bushing tool) ( flex tip removal tool) * not applicable. n ote: a a-400 superheater compressed air heating tool shown on page 10-2 can be used for installation. another option is the steinel general purpose hot-air heating t ool shown on page 10-13. tooling selection guide: mil-c-28748 series
shielded contacts 8-71 catalog 1654025 dimensions are in millimeters dimensions are shown for usa: 1-800-522-6752 south america: 55-11-3611-1514 revised 12-04 and inches unless otherwise reference purposes only. canada: 1-905-470-4425 japan: 81-44-900-5102 specified. v alues in brackets specifications subject mexico: 01-800-733-8926 singapore: 65-4866-151 www.tycoelectronics.com are u.s. equivalents. to change. c. america: 52-55-5-729-0425 uk: 44-1793-528171 8 e l e c t r i c a l i n t e r c o n n e c t p r o d u c t s soldertacts shielded one-piece solder contacts (continued) c ontact united states c able diameter r aychem m ilitary air force wire s oldertacts size polarity cable type specification drawing no. jod sod dod cod (awg) part number series i, iii, and iv m39029/60 a 3 .81?.94 3.10?.32 1.52?.84 . 48?.09 22?4 d-602-0122 8 p coaxial [.150-.234] [.150-.170] [.060-.151] [.019-.043] m39029/59 a 3.81?.94 3.10?.32 1.52?.84 .48?.09 22?4 d-602-0123 8 s coaxial [.150-.234] [.150-.170] [.060-.151] [.019-.043] m 39029/76 a 9 15304-1 1 .27?.62 1.68?.13 . 91?.73 .23?58 2 6?0 d-602-0140 16 p coaxial [.050-.103] [.066-.084] [.036-.068] [.009-.023] m39029/77 a 915305-1 1.27?.62 1.68?.13 .91?.73 .23?58 26?0 d-602-0141 16 s coaxial [.050-.103] [.066-.084] [.036-.068] [.009-.023] m39029/76 a 915304-2 ? .64?.09 .23?58 26?0 d-602-0142 16 p twisted pair [.025-.043] [.009-.023] m39029/77 a 915305-2 ? .64?.09 .23?58 26?0 d-602-0143 16 s twisted pair [.025-.043] [.009-.023] m39029/28 a 915307-1 1.47?.10 1.68?.39 1.12?.03 .48?89 24?2 d-602-0144 12 p coaxial [.058-.122] [.066-.094] [.044-.080] [.019-.035] m39029/75 a 915308-1 1.47?.10 1.68?.39 1.12?.03 .48?89 24?2 d-602-0145 12 s coaxial [.058-.122] [.066-.094] [.044-.080] [.019-.035] m39029/28 a 915307-3 .74?.45 .48?89 22?6 d-602-0146 12 p twisted pair [.029-.057] [.019-.035] m39029/75 a 915308-3 ? .74?.45 .48?89 22?6 d-602-0147 12 s twisted pair [.029-.057] [.019-.035] m39029/28 a 915307-2 1.90?.81 2.54?.97 1.27?.62 .48?89 22, 28 d-602-0150 12 p coaxial [.075-.150] [.100-.117] [.050-.103] [.019-.035] m39029/75 a 915308-2 1.90?.81 2.54?.97 1.27?.62 .48?89 22, 28 d-602-0151 12 s coaxial [.075-.150] [.100-.117] [.050-.103] [.019-.035] 8340712-os-01 2.49?.42 1.68?.05 .76?.24 .27?79 24?6 d-602-1 108 8 s twisted pair b [.098-.135] [.066-.120] [.030-.049] [.01 1-.031] 8340713-os-01 2.49?.42 1.68?.05 .76?.24 .27?79 24?6 d-602-1109 8 p twisted pair b [.098-.135] [.066-.120] [.030-.049] [.01 1-.031] 2.49?.76 1.68?.30 .91?.78 .23?89 22?6 d-602-1110 8 s triaxial [.098-.148] [.066-.130] [.036-.070] [.009-.035] 2.49?.76 1.68?.30 .91?.78 .23?89 22?6 d-602-1111 8 p triaxial [.098-.148] [.066-.130] [.036-.070] [.009-.035] 8340712-ol-01 2.49?.42 1.68?.05 .76?.24 .27?79 24?6 d-602-1112 8 s twisted pair b [.098-.135] [.066-.120] [.030-.049] [.011-.031] 8340713-ol-01 2.49?.42 1.68?.05 .76?.24 .27?79 24?6 d-602-1 1 13 8 p twisted pair b [.098-.135] [.066-.120] [.030-.049] [.011-.031] m39029/90 a 8912020-os-01 3.68 .64?.29 .27?74 24?6 dk-602-0156-n-1 8 p t winaxial c [.145 ] max. [.029-.051] [.011-.029] m39029/90 a 8912020-dl-01 4.11 .64?.29 .27?74 24?6 dk-602-0156-n-2 8 p twinaxial c [.162] max. [.029-.051] [.011-.029] a these soldertacts contacts are intermateable and intermountable with contacts qualified to indicated specification; they replace crimp-style termination. b these soldertacts contacts are designed for shielded twisted pair cable per mil-std-1553b. c these soldertacts contacts are designed for databus contacts per mil-std-1553b. s oldertacts product construction, mil-c-38999 series soldertacts series: mil-c-38999, series i, ii,i ii, iv circular connectors jacket (jod) shield (sod) dielectric (dod) conductor (cod)
shielded contacts 8-72 catalog 1654025 dimensions are in millimeters dimensions are shown for usa: 1-800-522-6752 south america: 55-11-3611-1514 revised 12-04 and inches unless otherwise reference purposes only. canada: 1-905-470-4425 japan: 81-44-900-5102 specified. v alues in brackets specifications subject mexico: 01-800-733-8926 singapore: 65-4866-151 www.tycoelectronics.com are u.s. equivalents. to change. c. america: 52-55-5-729-0425 uk: 44-1793-528171 soldertacts shielded one-piece solder contacts (continued) c ontact united states c able diameter (in inches) r aychem military air force w ire soldertacts size polarity cable type specification drawing no. j od sod dod cod ( awg) part number series i, iii, and iv m39029/90 a 8912020-el-01 4.50 max. .74-1.30 .24-.74 24?6 dk-602-0156-n-3 8 p twinaxial c [ .177] [.029?051] [.011?029] m39029/91 a 8912019-os-01 3 .68 max. .74-1.30 .24-.74 24?6 dk-602-0157-n-1 8 s twinaxial c [.145] [.029?051] [.011?029] m 39029/91 a 8 912019-dl-01 4.12 max. .74-1.30 .24-.74 2 4?6 dk-602-0157-n-2 8 s twinaxial c [.162] [.029?051] [.011?029] m39029/91 a 8912019-el-01 4 .50 max. .74-1.30 .24-.74 24?6 dk-602-0157-n-3 8 s twinaxial c [ .177] [.029?051] [.011?029] m 39029/90 a 8 912020-ol-01 4 .67 max. 20 dk-602-0169-1 8 p twinaxial c [.184] m39029/91 a 8912019-ol-01 4.67 max. 20 dk-602-0170-1 8 s twinaxial c [ .184] s eries ii m39029/76 a 915304-1 1 .27-2.62 1.68-2.13 .91-1.73 .23-.58 26?0 d -602-0140 16 p coaxial [.050?103] [.066?084] [.036?068] [ .009?023] m 39029/77 a 9 15306-1 1.27-2.62 1.68-2.13 .91-1.73 .23-.58 2 6?0 d-602-0171 1 6 s c oaxial [.050?103] [.066?084] [.036?068] [.009?023] m39029/76 a 915304-2 .64-1.09 .23-.58 26?0 d-602-0142 16 p twisted pair [.025?043] [.009?023] m39029/77 a 915306-2 .64-1.07 .23-.58 26?0 d-602-0174 16 s twisted pair [.025?042] [.009?023] a these soldertacts contacts are intermateable and intermountable with contacts qualified to indicated specification; they replace crimp-style termination. b these soldertacts contacts are designed for shielded twisted pair cable per mil-std-1553b. c these soldertacts contacts are designed for databus contacts per mil-std-1553b. engineering convection soldertacts part numbers standard (hot air) heating repair contact contact series (d-602-) (termination at-1319 wand insertion removal instructions) adapter tool tool* 999 0140/0141 es61226 at-1319-78 ad-1565 m81969/8-07 m81869/8-08 size 16 0142/0143 es61224 or or 0171 es61226 at-1319-27 ad-1572 m81969/14-03 m81969/14-03 0174 es61224 999 0144/0145 es61206 at-1319-24 ad-1566 m81969/8-09 m81969/8-10 size 12 0146/0147 es61218 or or 0150/0151 es61223 m81969/14-04 m81969/14-04 999 0122/0123 es61 179 at-1319-22 ad-1568 size 8 1108/1109 es61172 m81969/14-06 1110/1111 es61172 a t-1319-22 ad-1568 or 1112/1113 es61184 and and astro atbx-2277 0156/0157-x es61231 a t-1319-14 ad-1480 0169/0170-x es61235 *tyco electronics does not provide this tool. see connector manufacturer. note: aa-400 superheater compressed air heating tool shown on page 10-2 can be used for installation. another option is the steinel general purpose hot-air heating tool shown on page 10-13. soldertacts series: mil-c-38999, series i, ii,i ii, iv circular connectors (continued) tooling selection guide
shielded contacts 8-73 catalog 1654025 dimensions are in millimeters dimensions are shown for usa: 1-800-522-6752 south america: 55-11-3611-1514 revised 12-04 and inches unless otherwise reference purposes only. canada: 1-905-470-4425 japan: 81-44-900-5102 specified. v alues in brackets specifications subject mexico: 01-800-733-8926 singapore: 65-4866-151 www.tycoelectronics.com are u.s. equivalents. to change. c. america: 52-55-5-729-0425 uk: 44-1793-528171 8 e l e c t r i c a l i n t e r c o n n e c t p r o d u c t s soldertacts shielded one-piece solder contacts (continued) cable diameter s oldertacts size polarity cable type jod sod dod cod (awg) d-602-0278 16 p coaxial 1.52?.92 1.85?.18 .64?.91 .23?74 24?2 [.060-.115] [.073-.086] [.025-.075] [.009-.029] d-602-0279 16 s coaxial 1.52?.92 1.85?.18 .64?.91 .23?74 24?2 [.060-.1 15] [.073-.086] [.025-.075] [.009-.029] d-602-0288 16 p twisted pair .74?.40 .23?74 24?2 [.029-.055] [.009-.029] d-602-0289 16 s twisted pair .74?.40 .23?74 24?2 [.029-.055] [.009-.029] *these soldert acts contacts belong to the raychem ?ubminiature?series of contacts, which are designed for use in commercial connectors. tooling selection guide engineering convection contact contact soldertacts part numbers standard (hot air) heating removal series (d-602-) (termination at-1319 repair insertion tool instructions) adapter w and tool submin 0278/0279 es61170 at-1319-12 ad-1481 * ad-1447 0288/0289 es61414 *not applicable. note: aa-400 superheater compressed air heating tool shown on page 10-2 can be used for installation. another option is the steinel general purpose hot-air heating tool shown on page 10-13. s oldertacts product construction, submin series soldertacts series: subminiature* raychem cable diameter jacket (jod) shield (sod) dielectric (dod) conductor (cod)
shielded contacts 8-74 catalog 1654025 dimensions are in millimeters dimensions are shown for usa: 1-800-522-6752 south america: 55-11-3611-1514 revised 12-04 and inches unless otherwise reference purposes only. canada: 1-905-470-4425 japan: 81-44-900-5102 specified. v alues in brackets specifications subject mexico: 01-800-733-8926 singapore: 65-4866-151 www.tycoelectronics.com are u.s. equivalents. to change. c. america: 52-55-5-729-0425 uk: 44-1793-528171 soldertacts shielded one-piece solder contacts (continued) contact cable diameter m ilitary w ire raychem s ize polarity cable type s pecification* j od sod dod cod (awg) soldertacts m 39029/74-400 2 .39?.56 1.96?.49 1.32?.06 .28?74 2 4?2 d-602-0094 12 p coaxial [.094-.140] [.077-.098] [.052-.081] [.011-.029] m39029/73-397 2.39?.56 1.96?.49 1.32?.06 .28?74 24?2 d-602-0095 12 s coaxial [ .094-.140] [.077-.098] [.052-.081] [.011-.029] m39029/74-401 . 74?.45 .28?74 24?2 d-602-0104 12 p twisted pair [ .029-.057] [.011-.029] m 39029/73-398 . 74?.45 .28?74 2 4?2 d-602-0105 12 s twisted pair [.029-.057] [.011-.029] m39029/74-399 3.05?.68 3.10?.15 2.36?.67 .28?74 24?2 d-602-0106 12 p large coaxial [ .120-.145] [.122-.124] [.093-.105] [.011-.029] m 39029/73-396 3 .05?.68 3.10?.15 2.36?.67 .28?74 2 4?2 d-602-0107 12 s large coaxial [.120-.145] [.122-.124] [.093-.105] [.011-.029] * these soldertacts contacts are on qualified parts list for indicated specification. t ooling selection guide engineering convection raychem standard (hot air) heating repair contact contact special soldertacts (t ermination a t -1319 w and insertion removal t ools part number instructions) adapter t ool t ool d-602-0094/0095 es61 128 a t -1319-19 ad-1494 ad-1527 ad-1527 ad-1496 d-602-0106/0107 es61134 rev. d rev. c (m81969/14-04) (m81969/14-04) (twisted) d-602-0104/0105 es61129 note: aa-400 superheater compressed air heating tool shown on page 10-2 can be used for installation. another option is the steinel general purpose hot-air heating tool shown on page 10-13. raychem soldertacts size polarity cable type contact military reference specification d-602-0185 16 socket coaxial d-602-0094 12 pin coaxial m39029/74 d-602-0093* 12 socket coaxial m39029/73 d-602-0106 12 pin coax (large) m39029/74 d-602-0189* 12 socket coax (large) m39029/73 *these soldertacts contacts are intermateable with m39029/73, but are not on qpl. raychem soldertacts size polarity cable type contact military reference specification d-602-0186 8 pin twisted pair m39029/96 d-602-0187 8 socket twisted pair m39029/95 dk-602-0186-2 8 pin sh. twisted pair m39029/96 dk-602-0187-2 8 socket sh. twisted pair m39029/95 ** these soldertacts contacts are designed for shielded twisted pair cable per mil-std-1553b. soldertacts series: mil-c-83723 soldertacts series: dod-c-83527 soldertacts series: dod-c-83527 (data bus contacts)**
shielded contacts 8-75 catalog 1654025 dimensions are in millimeters dimensions are shown for usa: 1-800-522-6752 south america: 55-11-3611-1514 revised 12-04 and inches unless otherwise reference purposes only. canada: 1-905-470-4425 japan: 81-44-900-5102 specified. v alues in brackets specifications subject mexico: 01-800-733-8926 singapore: 65-4866-151 www.tycoelectronics.com are u.s. equivalents. to change. c. america: 52-55-5-729-0425 uk: 44-1793-528171 8 e l e c t r i c a l i n t e r c o n n e c t p r o d u c t s soldertacts shielded one-piece solder contacts (continued) r aychem soldertacts size polarity r eference d-600-0071 for shielded twisted pair d-600-0116 for size 8 dod-c-83527 series d-600-0125 for size 8 mil-c-38999 series, for twisted pair performance the performance of soldertacts contacts is defined by the applicable raychem specification con- trol drawing (scd) and raychem specification d-6002. products on quali- fied product lists meet the requirements of the base specification. termination termination of soldertacts contacts is defined in the appr opriate raychem engineering standar d. to obtain a copy, contact tyco electronics. soldertacts series: grommets


▲Up To Search▲   

 
Price & Availability of 11121113

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X